Skip to main content

Fan Settings

FOME can control two cooling fans, each on its own output. Each fan can switch on and off with coolant temperature, or run at a variable speed from a table. You can also run a fan with the A/C, stop it at speed or while the engine is stopped, and add idle air to cover the electrical load. Settings are under Base Engine > Fans.

How it works​

Each fan is decided independently, from the same list of conditions. The first condition that applies wins:

  1. Test Fan was pressed in the last 3 seconds: the fan runs, whatever else is true.
  2. Ignition is off: the fan is off.
  3. The engine is cranking: the fan is off.
  4. Disable when engine stopped is on and the engine isn't running: the fan is off.
  5. The coolant temperature sensor has failed: the fan is on.
  6. Vehicle speed is above Disable above speed: the fan is off.
  7. Enable with AC is on and the A/C is on: the fan is on.
  8. Coolant is above On temperature: the fan is on.
  9. Coolant is below Off temperature: the fan is off.
  10. Coolant is between the two: the fan keeps its previous state.

The gap between the on and off temperatures is the hysteresis. It stops the fan flicking on and off around a single temperature.

The fan state group in your log shows which of these conditions is active: engine stopped, broken CLT, enabled for AC, hot, cold and above disable speed.

PWM fans​

With Fan control type set to PWM, the conditions above still decide whether the fan should run. When it should, the duty comes from a table instead of being 100%. When it shouldn't, the duty is 0%. A table cell of 0% counts as the fan being off.

Each fan has one table for A/C off and one for A/C on, under Base Engine > Fans > PWM fans. The A/C on table is used whenever the A/C is on, even if Enable with AC is off for that fan. The tables are indexed by coolant temperature and by a second source that you pick with PWM table X axis, such as vehicle speed.

If the coolant sensor fails, or the chosen X axis source isn't available, the fan runs at Safety duty.

Disable above speed​

Set Disable above speed to stop a fan once ram air is cooling the radiator. It only takes effect when the ECU has a valid vehicle speed reading. If the speed sensor is missing or fails, the fan is never turned off because of speed. A value of 0 turns the feature off.

Idle adder​

Fans draw a lot of current, which loads the alternator and the engine. Idle adder adds idle position while that fan's output is on. It is applied to the open loop idle position along with the A/C adder, as described in Idle Settings.

Settings​

Each fan has its own dialog, Fan 1 and Fan 2.

SettingUnitsDescription
OutputThe pin that drives the fan relay or fan.
Output modeDefault turns the relay on with a high output. Default inverted switches to ground when on. The open collector modes are only needed if the relay runs at a different voltage to the ECU, and may need an external pull-up resistor or protection diode. Hidden in PWM mode.
Fan control typeOn/Off or PWM.
On temperatureCCoolant temperature above which the fan turns on.
Off temperatureCCoolant temperature below which the fan turns off.
PWM table X axisThe second axis of the PWM duty tables. Only shown in PWM mode.
Enable with ACRun the fan whenever the A/C is on.
Disable when engine stoppedKeep the fan off while the engine is not running.
Disable above speedkphKeep the fan off above this vehicle speed. 0 turns it off.
Idle adder%Idle position added while this fan is on.

PWM Settings applies to both fans and is only shown when either one uses PWM.

SettingUnitsDescription
PWM frequencyHzSwitching frequency of the fan outputs in PWM mode. Check what your fan or driver module expects.
Safety duty%Duty used if the coolant sensor fails in PWM mode.

Setup​

  1. Set Output and Output mode for each fan, then use Test Fan 1 and Test Fan 2 to check each one. The button runs the fan for a few seconds, even with the engine off.
  2. Set the temperatures. A reasonable start is the main fan on at 95 °C and off at 93 °C, and the second fan on at 100 °C and off at 98 °C. Keep about 2 °C between a fan's on and off values. The right values depend on your car.
  3. Turn on Enable with AC for both fans. The A/C adds heat in the condenser, which the fans need to move away.
  4. Leave Disable when engine stopped off unless you have a reason to use it.
  5. Set the idle adders. Watch the idle position on a TunerStudio gauge with closed loop idle on, and turn each fan on in turn with Test Fan. Note how far the idle position rises, and enter that as the Idle adder for the fan.
  6. For PWM fans, set Safety duty high enough to cool the engine, then fill in the duty tables. Start with 0% below the cooling threshold and rise to 100% at the top of your safe operating range.
note

If Enable with AC is on, the A/C idle adder and the fan adders add together when the A/C is on. Either keep the A/C adder low, or use only the A/C adder and leave the fan adders at 0.

Checking it works​

  • Watch the fan indicators in the Fan Settings dialog, or the fan on/off state in your log, to see when each fan is on.
  • In PWM mode, log the fan duty and the X axis value, and check the duty follows the table.
  • Check that the fan comes on near the On temperature and goes off near the Off temperature.

If it fails​

  • Coolant sensor failed: the fan runs. In PWM mode it runs at Safety duty. This overrides Disable above speed, Enable with AC and the temperature thresholds. Ignition off, cranking, Disable when engine stopped and the 3 s fan test still take priority.
  • Vehicle speed sensor missing or failed: Disable above speed has no effect, and the fan follows the other conditions.
  • PWM X axis source not available: a fan that should run does so at Safety duty.

Troubleshooting​

SymptomLikely cause
Fan runs all the timeThe coolant sensor has failed. See Coolant Temperature.
Fan stops when drivingDisable above speed is set below your road speed.
Fan doesn't come on with the A/CEnable with AC is off, or the A/C isn't running. See Air Conditioning Settings.
Fan flicks on and offOn and off temperatures are too close together.
Fan is off with the key on and the engine stoppedDisable when engine stopped is on.
Test Fan does nothingWrong Output or Output mode, or wiring.
PWM fan doesn't change speedFan control type isn't PWM, or the duty table has the same value everywhere.