Cranking Ignition
While the engine is cranking, FOME uses its own ignition timing and dwell instead of the running tables, because spark timing at 200 to 300 RPM is very different from timing at idle. The engine counts as cranking until its speed reaches the Cranking RPM limit (see Cranking RPM Limit), after which it uses the running Ignition Advance Table and Dwell.
Settings are under Cranking > Cranking settings > Ignition, plus Cranking > Cranking ignition advance when table mode is selected.
How it works
The cranking advance can come from one of two sources, chosen with Timing Advance mode.
- Fixed (auto taper): you enter a single Fixed cranking advance. FOME holds that angle up to half the Cranking RPM limit, then blends towards the running advance, reaching it at the Cranking RPM limit. The timing therefore hands over smoothly to the running table.
- Table: the advance is read from the Cranking ignition advance curve against RPM and used as is, with no blending towards the running table. Use this if you need a specific timing at each cranking speed, for example retarded for a high-compression engine on a weak battery.
Dwell while cranking is a single fixed time, Fixed Cranking Dwell, instead of the voltage-corrected table used when running.
Settings
| Setting | Units | Description |
|---|---|---|
| Timing Advance mode | - | Fixed (auto taper) or Table |
| Fixed cranking advance | deg | Advance before TDC at the start of cranking. Only shown in fixed mode |
| Fixed Cranking Dwell | ms | Coil dwell time while cranking |
| Cranking ignition advance (curve) | deg vs RPM | Advance by RPM. Only available in table mode |
| Use Advance Corrections for cranking | - | Under Cranking > Cranking settings > Advanced. Apply the IAT, CLT, idle and DFCO timing corrections during cranking too |
Advance corrections
Normally the ignition corrections (IAT, CLT, idle timing control and DFCO retard) aren't applied while cranking. Use Advance Corrections for cranking enables them, but only if Timing Mode is not set to fixed timing. Most setups don't need it.
Setup
- Start in fixed mode with a conservative value. 5 to 10° works for most engines.
- Set Fixed Cranking Dwell to suit your coils. Check your coil's documentation, as the right value depends on the coil and voltage.
- Crank the engine and watch the timing. If it kicks back against the starter or cranks slowly, lower the advance. If it is slow to catch, check the fuel first, then the timing.
- Only move to table mode if you need different timing at different cranking speeds.
Too much cranking advance can cause the engine to kick back against the starter. Start with less and work up.
Checking it works
Watch the ignition timing channel (Ign: Timing Base) in the logs while cranking. In fixed mode it should start at your value and rise gradually as the engine speeds up. In table mode it should follow the curve. A timing light confirms it matches.
Troubleshooting
| Symptom | Likely cause |
|---|---|
| Kicks back when cranking | Cranking advance too high |
| Weak spark or misfires when cranking | Fixed Cranking Dwell too short, or low battery voltage |
| Runs poorly just after starting | Cranking RPM limit too high or too low, so the switch to running timing happens at the wrong time |
| Table is not available in the menu | Timing Advance mode is set to fixed |